19 Harley St, London, W1G 9QJ, UK

Replantation of lamina spinous process ligament complex and miniature titanium plate shaping internal fixation in the treatment of tumors in the spinal canal – Lumbar Fusion

Day Case Lumbar Fusion Surgery

This article discusses a study that explored the clinical efficacy of laminospinous process ligament complex reimplantation combined with mini-titanium plate fixation in the treatment of thoracolumbar intraspinal tumors. A retrospective analysis was performed on 43 cases, with 27 cases undergoing the reimplantation and plate fixation procedure, and 16 cases undergoing laminectomy combined with pedicle screw internal fixation. The study compared various factors such as operation time, blood loss, drainage tube removal time, cerebrospinal fluid leakage, spinal instability, and the incidence of secondary spinal stenosis between the two groups. The results showed that the reimplantation and plate fixation procedure effectively reconstructed the spinal canal and posterior column structure, reducing the incidence of cerebrospinal fluid leakage and secondary spinal stenosis. The laminar fusion rate was high

Summarised by Mr Mo Akmal – Lead Spinal Surgeon
The London Spine Unit : most advanced treatment hospital on Harley Street UK

Published article

S: The application of laminospinous process ligament complex reimplantation combined with mini titanium plate fixation during thoracolumbar intraspinal tumor resection can effectively reconstruct the spinal canal and posterior column structure, reduce the incidence of cerebrospinal fluid leakage and secondary spinal stenosis. The laminar fusion rate is high.

Lumbar Fusion Surgery Expert. Best Spinal Surgeon UK
BMC Musculoskelet Disord. 2023 Nov 10;24(1):873. doi: 10.1186/s12891-023-06984-9.ABSTRACTOBJECTIVE: Purpose This study aims to explore the clinical efficacy of laminospinous process ligament complex reimplantation combined with mini-titanium plate fixation in the treatment of thoracolumbar intraspinal tumors.METHODS: A retrospective analysis was performed on 43 cases of intraspinal tumors treated with thoracolumbar intraspinal tumor resection from August 2018,

BMC Musculoskelet Disord. 2023 Nov 10;24(1):873. doi: 10.1186/s12891-023-06984-9.

ABSTRACT

OBJECTIVE: Purpose This study aims to explore the clinical efficacy of laminospinous process ligament complex reimplantation combined with mini-titanium plate fixation in the treatment of thoracolumbar intraspinal tumors.

METHODS: A retrospective analysis was performed on 43 cases of intraspinal tumors treated with thoracolumbar intraspinal tumor resection from August 2018 to March 2021, and 27 cases underwent laminospinous process ligament complex reimplantation combined with micro titanium plate shaping. Fixation (laminar replantation group), and 16 patients underwent laminectomy combined with pedicle screw internal fixation (laminectomy group). The operation time, blood loss, drainage tube removal time, cerebrospinal fluid leakage, spinal instability, and the incidence of secondary spinal stenosis were compared between the two groups. The pain VAS score, ODI score, and modified Macnab at the last follow-up were compared between the two groups. And the laminar fusion rate of the laminoplasty group was measured.

RESULTS: Both groups successfully completed the surgery and obtained complete follow-up. The incidence of cerebrospinal fluid leakage and secondary spinal canal stenosis in the laminectomy group was lower than that in the laminectomy group, and the difference was statistically significant (P < 0.05). There was no statistically significant difference in the incidence of spinal instability between the two groups (P > 0.05). The operation time and intraoperative blood loss in the laminectomy group were less than those in the laminectomy group, and the drainage tube removal time was earlier than that in the laminectomy group. The difference was statistically significant (P < 0.05). At the final follow-up, there was no statistically significant difference in the pain VAS score, ODI score, and modified Macnab between the two groups (P > 0.05), but they were all significantly improved compared with preoperative ones. Fusion evaluation was conducted on the laminoplasty group. Two years after surgery, the fusion rate was 97.56% (40/41).

S: The application of laminospinous process ligament complex reimplantation combined with mini titanium plate fixation during thoracolumbar intraspinal tumor resection can effectively reconstruct the spinal canal and posterior column structure, reduce the incidence of cerebrospinal fluid leakage and secondary spinal stenosis. The laminar fusion rate is high.

PMID:37950233 | PMC:PMC10636857 | DOI:10.1186/s12891-023-06984-9

The London Spine Unit : most advanced treatment hospital on Harley Street UK

Read the original publication:

Replantation of lamina spinous process ligament complex and miniature titanium plate shaping internal fixation in the treatment of tumors in the spinal canal

Related Posts

0/5 (0 Reviews)

Trusindex Reviews

London Spine Unit Harley Street Hospital

A Focus on High Quality Specialised Care

We are a specialist Private Hospital based on Harley Street, London UK The Harley Street Hospital, Day Surgery Hospital

We provide exclusive health services for individuals seeking Advanced medical, non-surgical or minimally invasive treatments. We are covered by All Insurance Companies apart from AXA PPP

Our Medical Director and Lead Spinal Surgeon Mr Mo Akmal MD is a world renowned Spine Specialist Consultant with over 20 years of experience. He and his team have developed revolutionary techniques to perform all types of Spinal Surgery as a Day Case procedure without traditional General Anaesthetic.

We are constantly improving our techniques for treatment and improving facilities for our patients.

Book your Appointment Now 
Check out our Reviews 
Check out our Patient Videos 
Check our Mr Akmal’s Profile

 

What our patients say ...

BMC Musculoskelet Disord. 2023 Nov 10;24(1):873. doi: 10.1186/s12891-023-06984-9.ABSTRACTOBJECTIVE: Purpose This study aims to explore the clinical efficacy of laminospinous process ligament complex reimplantation combined with mini-titanium plate fixation in the treatment of thoracolumbar intraspinal tumors.METHODS: A retrospective analysis was performed on 43 cases of intraspinal tumors treated with thoracolumbar intraspinal tumor resection from August 2018

Revolutionary Keyhole surgical technique to vaporise bulging discs

Dr Mo Akmal Medical Director
Dr Mo Akmal MD - Lead Spinal Surgeon

Laser Disc Surgery can be performed under local anaesthetic at The Harley Street Hospital.

Initial Consultation

with Consultant Spine Surgeon
£ 250
  • No Waiting Times
  • Top NHS affiliated Consultant
  • Includes Clinical Review and Report
  • Multidisciplinary discussion
  • Review of Previous Scans and Reports

Follow up Consultation

any appointment after initial consultation
£ 180
  • Top NHS affiliated Consultant
  • Includes Clinical Review and Report
  • Multidisciplinary discussion

High Resolution MRI Scan

any Single Region (3.0 Tesla)
£ 600
  • No waiting times
  • Includes Full Radiologist Report
  • Open or Closed MRI scan types
  • Copy of Scan on CD

Website Offer

Pre-Booked Online
£1130
£ 800
  • Initial Consultation
  • MRI Scan (Single Region)
  • Follow Up consultation
  • Same Day One Stop Visit
  • Full Medical and MRI scan Report
  • Copy of scan on CD
Popular

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810