19 Harley St, London, W1G 9QJ, UK

Repairing Angle of the Mandible Fractures With a Strut Plate.

Related Articles

Repairing Angle of the Mandible Fractures With a Strut Plate.

JAMA Otolaryngol Head Neck Surg. 2013 Jun 1;139(6):592-597

Authors: Guy WM, Mohyuddin N, Burchhardt D, Olson KL, Eicher SA, Brissett AE

Abstract
IMPORTANCE Despite multiple fixation techniques, the optimal method of repairing mandibular angle fractures remains controversial. OBJECTIVE To evaluate the outcomes when using a 3-dimensional, curved strut plate in repair of angle of the mandible fractures. DESIGN Retrospective cohort study. SETTING Level I trauma center at an academic institution in Harris County, Texas. PARTICIPANTS Patients with diagnostic codes involving angle of the mandible fractures that were repaired by the otolaryngology-head and neck surgery service from February 1, 2006, through February 28, 2011. EXPOSURE Open reduction internal fixation using either a 3-dimensional curved strut plate or any other type of repair technique for angle of the mandible fractures. MAIN OUTCOMES AND MEASURES Complication rates, postoperative complaints, and operative characteristics. RESULTS Ninety patients underwent qualifying procedures during the study period. A total of 68 fractures (76%) were repaired using the 3-dimensional curved strut plate and 22 (24%) were repaired using other methods. The revision surgery rate was 10% for the strut plate group (7 patients) and 14% for the non-strut plate group (3 patients), with no significant differences in rates of infection (3 [4%] vs 2 [9%]), dehiscence (4 [6%] vs 2 [9%]), malunion (1 [1%] vs 2 [9%]), nonunion (3 [4%] vs 0), hardware failure (1 [1%] vs 1 [5%]), malocclusion (2 [3%] vs 2 [9%]), and injury to the inferior alveolar nerve (1 [1%] vs 1 [5%]). The most common postoperative complaints were pain (13 [19%] vs 6 [27%]), followed by numbness (5 [7%] vs 2 [9%]), trismus (4 [6%] vs 3 [14%]), edema (3 [4%] vs 3 [14%]), and bite deformity (2 [3%] vs 2 [9%]), with a mean (range) follow-up time of 54.7 (2-355) days for the strut plate group vs 46.8 (8-308) days for the non-strut plate group. CONCLUSIONS AND RELEVANCE The 3-dimensional curved strut plate is an effective treatment modality for angle fractures, with comparable infection rates, low incidence of alveolar nerve injury, and trends for decreased length of operation, complications, and infections compared with other techniques.

PMID: 23787417 [PubMed – as supplied by publisher]

Repairing Angle of the Mandible Fractures With a Strut Plate | Cervical and Lumbar Disc Replacement Surgery in NJ | Spine Specialist

What our patients say ...

Consultant Spine Surgeon
Consultant Spine Surgeon
Consultant Spine Surgeon

Revolutionary Keyhole surgical technique to vaporise bulging discs

Laser Disc Surgery can be performed under local anaesthetic as a day case at our centre on the prestigious Harley Street.
Treatment of all spinal disorders

The London Spine Unit specialises in Minimally Invasive Treatments allowing rapid recovery and return to normal function.

UK's Leading Spine Surgeon

Mr Mo Akmal has developed revolutionary techniques to perform Day Case Spinal Surgery. We avoid traditional General Anaesthetic for all surgery.

Trusted by patients worldwide

The London Spine Unit provides the highest quality care to all patients and has VIP services for those seeking exceptional services.

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810