Menu
Menu
19 Harley St, London, W1G 9QJ, UK

Real-Time Imaging with the O-Arm for Skull Base Applications: A Cadaveric Feasibility Study.

Real-Time Imaging with the O-Arm for Skull Base Applications: A Cadaveric Feasibility Study.

J Neurol Surg B Skull Base. 2012 Oct;73(5):293-301

Authors: Raza SM, See AP, Lim M

Abstract
Introduction?Although intraoperative imaging/navigation has established its critical role in neurosurgery, its role in cranial base surgery is currently limited. Due to issues such as poor bony resolution and accuracy, surgeons have to rely on anatomic landmarks that can be distorted by pathology when drilling out critical structures. Though originally developed for spinal application, we hypothesized that the O-Arm could address the above issues for use in cranial base procedures. Methods?A cadaveric study was performed in which heads underwent a preprocedure scan via the O-Arm, a fluoroscopic device capable of providing three-dimensional images through the use of cone-beam technology. Preprocedure scans were taken and then registered to a Stealth S7 machine (Medtronic, Inc., Minneapolis, MN, USA). Key cranial base landmarks were identified on these scans and then subsequently identified under direct visualization after (1) endoscopic endonasal dissection and (2) a middle fossa approach. We then quantified the difference in distance between the preplanned and identified structure during surgery. This difference was considered the error. Results?For anterior cranial fossa structures, the mean error was 0.25?mm (anterior septum), 0.27?mm (left septum), and 0.32?mm (right septum). For middle fossa structures, the errors were: 0.11?mm (foramen spinosum), 0.44?mm (foramen rotundum), and 0.21?mm (foramen ovale). Conclusion?Based on this preliminary cadaveric study, we feel the O-Arm can provide the necessary imaging resolution at the skull base to be employed for intraoperative navigation during cranial base approaches (open and endoscopic). This study warrants further investigation into its clinical use in patients undergoing similar surgical procedures.

PMID: 24083119 [PubMed – as supplied by publisher]

Real-Time Imaging with the O-Arm for Skull Base Applications: A Cadaveric Feasibility Study.

J Neurol Surg B Skull Base. 2012 Oct;73(5):293-301

Authors: Raza SM, See AP, Lim M

Abstract
Introduction Although intraoperative imaging/navigation has established its critical role in neurosurgery, its role in cranial base surgery is currently limited. Due to issues such as poor bony resolution and accuracy, surgeons have to rely on anatomic landmarks that can be distorted by pathology when drilling out critical structures. Though originally developed for spinal application, we hypothesized that the O-Arm could address the above issues for use in cranial base procedures. Methods A cadaveric study was performed in which heads underwent a preprocedure scan via the O-Arm, a fluoroscopic device capable of providing three-dimensional images through the use of cone-beam technology. Preprocedure scans were taken and then registered to a Stealth S7 machine (Medtronic, Inc., Minneapolis, MN, USA). Key cranial base landmarks were identified on these scans and then subsequently identified under direct visualization after (1) endoscopic endonasal dissection and (2) a middle fossa approach. We then quantified the difference in distance between the preplanned and identified structure during surgery. This difference was considered the error. Results For anterior cranial fossa structures, the mean error was 0.25 mm (anterior septum), 0.27 mm (left septum), and 0.32 mm (right septum). For middle fossa structures, the errors were: 0.11 mm (foramen spinosum), 0.44 mm (foramen rotundum), and 0.21 mm (foramen ovale). Conclusion Based on this preliminary cadaveric study, we feel the O-Arm can provide the necessary imaging resolution at the skull base to be employed for intraoperative navigation during cranial base approaches (open and endoscopic). This study warrants further investigation into its clinical use in patients undergoing similar surgical procedures.

PMID: 24083119 [PubMed - as supplied by publisher]

What our patients say ...

Consultant Spinal Surgeon
Consultant Spinal Surgeon
Consultant Spinal Surgeon
Consultant Spinal Surgeon
Consultant Spinal Surgeon
Consultant Spinal Anaesthetist

This surgical technique consists of a percutaneous approach for the treatment of small to medium size hernias of the intervertebral disc by laser energy. The main objective is to reduce the intradiscal pressure in the nucleus pulposus

Laser Disc Surgery can be performed under local anaesthetic as a day case at our centre on the prestigious Harley Street.
What is London spine unit and How it Works

The London Spine Unit was established in 2005 and has successfully treated over 5000 patients. All conditions are treated.

treatment of all spinal disorders

The London Spine Unit specialises in Minimally Invasive Treatments allowing rapid recovery and return to normal function

Trusted by patients worldwide

The London Spine Unit provides the highest quality care to all patients and has VIP services for those seeking exceptional services

Laser Spine Surgery Articles

SHADES of grey – The challenge of ‘grumbling’ cauda equina symptoms in older adults with lumbar spinal stenosis.
Abstract Diagnosing cauda equina syndrome is challenging in older adults with lumbar spinal stenosis. Understanding these challenges is vital for
Read more.
The influence of preoperative mental health on clinical outcomes after laminectomy in patients with lumbar spinal stenosis.
Abstract OBJECTIVE: The influence of preoperative mental health on health-related quality of life (HRQOL) in patients with lumbar spinal stenosis
Read more.
MicroRNA transcriptome analysis on hypertrophy of ligamentum flavum in patients with lumbar spinal stenosis.
Abstract Introduction: Molecular pathways involved in ligamentum flavum (LF) hypertrophy are still unclarified. The purpose of this study was to
Read more.
Salvage Strategy for Failed Spinal Fusion Surgery Using Lumbar Lateral Interbody Fusion technique: A Technical Note.
Abstract Introduction: Failed spinal fusion surgery sometimes requires salvage surgery when symptomatic, especially with postsurgical decrease in intervertebral disc height
Read more.
Integrated anatomy of the neuromuscular, visceral, vascular, and urinary tissues determined by MRI for a surgical approach to lateral lumbar
Abstract Introduction: To comprehensively investigate the anatomy of the neuromuscular, visceral, vascular, and urinary tissues and their general influence on
Read more.
Clinical Outcomes of Treating Cervical Adjacent Segment Disease by Anterior Cervical Discectomy and Fusion Versus Total Disc Replacement: A Systematic
Related Articles Clinical Outcomes of Treating Cervical Adjacent Segment Disease by Anterior Cervical Discectomy and Fusion Versus Total Disc Replacement:
Read more.

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810