Occult spinous process fractures associated with interspinous process spacers

STUDY DESIGN: Prospective observational study. OBJECTIVE: To provide a more accurate estimate of the rate of acute spinous process fractures associated with IPS surgery. SUMMARY OF BACKGROUND DATA: Biomechanical cadaveric studies have suggested adequate spinous process strength to support placement of interspinous process spacers (IPS). Postoperative spinous process fractures have been reported in one%-to 5.8% of patients in previous series based on routine biplanar radiographic evaluation. However, most fractures occur between the base and midportion of the spinous process in an area that is typically difficult to visualize on plain radiographs due to device design. METHODS: All patients underwent preoperative biplanar plain radiographs and computed tomography (CT) of the lumbar spine to confirm anatomy favorable for IPS placement and rule out fracture or spondylolysis. Postoperatively, all patients underwent repeat CT imaging within six months of surgery, biplanar radiographs at two weeks, six weeks, three months, six months, and one year. All studies were reviewed independently by a neuroradiologist and two orthopedic spine surgeons. RESULTS: Fifty implants (38 L4-5, 12 L3-4) were placed in 38 patients who completed follow-up and were included in final analysis. Three IPS designs were included (34 Medtronic X-STOP titanium, 8 X-STOP PEEK, 8 Lanx Aspen). Postoperative CT revealed 11 nondisplaced spinous process fractures in 11 patients (28.9% of patients, 22% of levels). Five fractures were associated with mild to moderate lumbar back pain and six fractures were asymptomatic. No patient reported a traumatic incident. No fracture was identifiable on plain radiographs. One fracture displaced during follow-up evaluation. Three patients underwent IPS removal and laminectomy. Three fractures healed by CT in one year. Overall, patients with fractures tended toward poorer outcomes by Zurich Claudication Questionnaire (ZCQ) (28.5% vs. 34.8% improvement in symptom severity, P = 0.496; 21.4% vs. 30.7% improvement in physical function, P = 0.199) and tended toward lower satisfaction rates (50% vs. 73.7%, P = 0.24) at one year compared to patients without fracture. CONCLUSION: Interspinous process spacer surgery appears associated with a higher rate of early postoperative spinous process fracture than previously reported. In all cases, in this series, plain radiographs were inadequate to identify fractures because all fractures were initially minimal or nondisplaced, many patients were osteopenic, and the metallic wings of the devices often obscured fractures. Moreover, in most patients, fractures were associated with mild or no acute localized pain. This study suggests that unrecognized spinous process fracture may be responsible for a significant number of patients who experience unsatisfactory outcome after IPS surgery. CT imaging is required to identify the vast majority of such fractures

Keywords : Aged,Aged,80 and over,analysis,Back,Back Pain,Boston,complications,diagnosis,diagnostic imaging,etiology,Female,Follow-Up Studies,Humans,injuries,Laminectomy,Lumbar Vertebrae,Magnetic Resonance Imaging,Male,methods,Middle Aged,Pain,Patients,Postoperative Care,Postoperative Complications,Preoperative Care,Prospective Studies,Prostheses and Implants,Spinal Fractures,Spinal Stenosis,Spine,Spondylolysis,surgery,Surveys and Questionnaires,Titanium,Tomography,X-Ray Computed,Treatment Outcome,Universities,, Spinous,Process,Fractures,Associated,With, facet denervation

Date of Publication : 2011 Jul 15

Authors : Kim DH;Tantorski M;Shaw J;Martha J;Li L;Shanti N;Rencu T;Parazin S;Kwon B;

Organisation : Tufts University School of Medicine, 125 Parker Hill Ave., Boston, MA 02120, USA. dhkim@caregroup.harvard.edu

Journal of Publication : Spine (Phila Pa 1976 )

Pubmed Link : https://www.ncbi.nlm.nih.gov/pubmed/21343860

The London Spine Unit : Harley Street UK. Specialists in Cutting Edge Technologies for Spinal Surgery

Make an Appointment 

Trustpilot Reviews
Doctify Reviews
Top Doctor Reviews

Occult spinous process fractures associated with interspinous process spacers | Acupuncture for joint pain

What our patients say ...

Consultant Spine Surgeon
Consultant Spine Surgeon
Consultant Spine Surgeon

This surgical technique consists of a percutaneous approach for the treatment of small to medium size hernias of the intervertebral disc by laser energy. The main objective is to reduce the intradiscal pressure in the nucleus pulposus

Laser Disc Surgery can be performed under local anaesthetic as a day case at our centre on the prestigious Harley Street.
What is London spine unit and How it Works

The London Spine Unit was established in 2005 and has successfully treated over 5000 patients. All conditions are treated.

treatment of all spinal disorders

The London Spine Unit specialises in Minimally Invasive Treatments allowing rapid recovery and return to normal function

Trusted by patients worldwide

The London Spine Unit provides the highest quality care to all patients and has VIP services for those seeking exceptional services

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810