In vivo deformation, surface damage, and biostability of retrieved Dynesys systems

STUDY DESIGN: Retrospective retrieval analysis. OBJECTIVE: To evaluate wear, deformation and biodegradation within retrieved polycarbonate urethane (PCU) components of Dynesys systems. SUMMARY OF BACKGROUND DATA: The Dynesys Dynamic Stabilization System (Zimmer Spine) consists of pedicle screws (Ti alloy), polycarbonate urethane (PCU) spacers, and a polyethylene-terephthalate cord. METHODS: Seventeen retrieved (mean implantation: 2.5 years, range: 0.7-7.0 years) and 2 exemplar implant systems were available. Reasons for revision were persistent pain (16/17), infection (1/17), and/or screw loosening (11/17), with 1/17 case of implant migration. Optical microscopy, microCT, and scanning electron microscopy were conducted to evaluate PCU spacer wear and deformation. Attenuated total reflectance Fourier transform infrared spectroscopy was used to assess spacer surface chemical composition. RESULTS: Retrieved spacer components exhibited permanent bending deformation (mean: 4.3 degrees , range: 0.0 degrees -15.8 degrees ). We observed evidence of PCU spacer contact with pedicle screws, cords, and surrounding bony structures (74/75, 69/75, and 51/75 spacers, respectively). Relatively infrequent damage modes included PCU fracture (1/75 spacers) or cracking (2/75 spacers), as well as pedicle screw fracture (3/103 screws). PCU degradation products were identified in 10/75 spacers, which represented retrievals having significantly longer implantation times (mean: 4.3 years, range: 1.0-7.0 years). Of these spacers, 8/10 had degradation peaks identified along the side of the spacer where the material would have been in contact with bodily fluid. CONCLUSION: PCU spacers from retrieved Dynesys systems exhibited permanent deformation, focal regions of in vivo wear and surface damage. Chemical changes associated with PCU biodegradation were associated with longer-term retrievals. The most frequently observed complication was pedicle screw loosening, with 3 incidences of screw breakage in 2 patients. These retrieval data provide a crucial basis for developing in vitro tests to simulate in vivo damage and degradation of posterior dynamic motion preservation implants. Longer-term retrievals, as well as retrievals that include more recent design features (e.g., HA coating), will be useful to provide a greater context for the clinical implications of our short-term observations

Keywords : Adult,analysis,Bone Screws,Equipment Failure,Female,Humans,Incidence,Infection,Internal Fixators,Lumbar Vertebrae,Male,methods,Microscopy,Middle Aged,Motion,Pain,Patients,Reoperation,Retrospective Studies,Spine,surgery,Time,, Vivo,Deformation,Surface,Damage, hypermobility clinic london

Date of Publication : 2010 Nov 1

Authors : Ianuzzi A;Kurtz SM;Kane W;Shah P;Siskey R;van OA;Bindal R;Ross R;Lanman T;Buttner-Janz K;Isaza J;

Organisation : Exponent Inc., Philadelphia, PA, USA

Journal of Publication : Spine (Phila Pa 1976 )

Pubmed Link : https://www.ncbi.nlm.nih.gov/pubmed/20975485

The London Spine Unit : Harley Street UK. Specialists in Cutting Edge Technologies for Spinal Surgery

Make an Appointment 

Trustpilot Reviews
Doctify Reviews
Top Doctor Reviews

Tuberculous spondylodiscitis epidemiology, clinical features, treatment, and outcome | Abdominal wall pain treatment

What our patients say ...

Consultant Spine Surgeon
Consultant Spine Surgeon
Consultant Spine Surgeon

This surgical technique consists of a percutaneous approach for the treatment of small to medium size hernias of the intervertebral disc by laser energy. The main objective is to reduce the intradiscal pressure in the nucleus pulposus

Laser Disc Surgery can be performed under local anaesthetic as a day case at our centre on the prestigious Harley Street.
What is London spine unit and How it Works

The London Spine Unit was established in 2005 and has successfully treated over 5000 patients. All conditions are treated.

treatment of all spinal disorders

The London Spine Unit specialises in Minimally Invasive Treatments allowing rapid recovery and return to normal function

Trusted by patients worldwide

The London Spine Unit provides the highest quality care to all patients and has VIP services for those seeking exceptional services

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810