Published article

Percutaneous cement discoplasty procedure could make effect on the mobility or stiffness. The fusion of bone cement and endplate might have more biomechanical advantages, including of the decreasing rate of implant subsidence and dislocation, and the increase spine stability.
Lumbar Disc Replacement Expert. Best Spinal Surgeon UK

Abstract

Objective: To compare the biomechanical properties of percutaneous cement discoplasty (PCD) in the spinal column between different implant-endplate friction.

Methods: A validated L3-Scarumfinite element (FE) model was modified for simulation. In the PCD model, the L4/5 level was modified based on model 1 (M1) and model 2 (M2). In M1, the interaction between bone cement and endplate was defined as face-to-face contact with a friction coefficient of 0.3; in M2, the contact was defined as a Tie constraint. 7.5 N m moments of four physiological motions and axial load of 15, 100 and 400 N preload were imposed at the top of L3. The range of motion (ROM) and interface stress analysis of endplates, annulus fibrosus and bone cement of the operated level were calculated for comparisons among the three models.

Results: The ROM of M1 and M2 increased when compared with the intact model during flexion (FL) (17.5% vs 10.0%), extension (EX) (8.8% vs -8.8%), left bending (LB) (19.0% vs -17.2%) and left axial rotation (LR) (34.6% vs -3.8%). The stress of annulus fibrosus in M1 and M2 decreased in FL (-48.4% vs -57.5%), EX (-25.7% vs -14.7%), LB (-47.5% vs -52.4%), LR (-61.4% vs -68.7%) and axis loading of 100 N (-41.5% vs -15.3%), and 400 N (-27.9% vs -27.3%). The stress of upper endplate of M1 and M2 increased in FL (24.6% vs 24.7%), LB (82.2% vs 89.5%), LR (119% vs 62.4%) and axis loading of 100 N (64.6% vs 45.5%), and 400 N (58.2% vs 24.3%), but was similar in EX (2.9% vs 0.3%). The stress of lower endplate of M1 and M2 increased in FL (170.9% vs 175.0%), EX (180.8% vs 207.7%), LB (302.6% vs 274.7%), LR (332.4% vs 132.8%) and axis loading of 100 N (350.7% vs 168.6%), and 400 N (165.2% vs 106.7%).

Percutaneous cement discoplasty procedure could make effect on the mobility or stiffness. The fusion of bone cement and endplate might have more biomechanical advantages, including of the decreasing rate of implant subsidence and dislocation, and the increase spine stability.

Keywords: Biomechanical; Bone cement; Finite element analysis; Lumbar spinal stenosis; PMMA; Percutaneous cement discoplasty.

The London Spine Unit : best rated spine centre in the world
Read the original here:
Biomechanical Evaluation of Spinal Column after Percutaneous Cement Discoplasty: A Finite Element Analysis

Doctors Specialising in Dynamic Spine Stabilisation Surgery
Mr Mo Akmal MD
Mr Mo Akmal, MD, stands as a innovator in the ...

Related Posts

0/5 (0 Reviews)

Trusindex Reviews

London Spine Unit Harley Street Hospital

A Focus on High Quality Specialised Care

We are a specialist Private Hospital based on Harley Street, London UK The Harley Street Hospital, Day Surgery Hospital

We provide exclusive health services for individuals seeking Advanced medical, non-surgical or minimally invasive treatments. We are covered by All Insurance Companies apart from AXA PPP

Our Medical Director and Lead Spinal Surgeon Mr Mo Akmal MD is a world renowned Spine Specialist Consultant with over 20 years of experience. He and his team have developed revolutionary techniques to perform all types of Spinal Surgery as a Day Case procedure without traditional General Anaesthetic.

We are constantly improving our techniques for treatment and improving facilities for our patients.

Book your Appointment Now 
Check out our Reviews 
Check out our Patient Videos 
Check our Mr Akmal’s Profile

 

What our patients say ...

Abstract Objective: To compare the biomechanical properties of percutaneous cement discoplasty (PCD) in the spinal column between different implant-endplate friction. Methods: A validated L3-Scarumfinite element (FE) model was modified for simulation. In the PCD model, the L4/5 level was modified based on model 1 (M1) and model 2 (M2). In M1, the interaction between bone…

Revolutionary Keyhole surgical technique to vaporise bulging discs

Dr Mo Akmal Medical Director
Dr Mo Akmal MD - Lead Spinal Surgeon

Laser Disc Surgery can be performed under local anaesthetic at The Harley Street Hospital.

Initial Consultation

with Consultant Spine Surgeon
£ 250
  • No Waiting Times
  • Top NHS affiliated Consultant
  • Includes Clinical Review and Report
  • Multidisciplinary discussion
  • Review of Previous Scans and Reports

Follow up Consultation

any appointment after initial consultation
£ 180
  • Top NHS affiliated Consultant
  • Includes Clinical Review and Report
  • Multidisciplinary discussion

High Resolution MRI Scan

any Single Region (3.0 Tesla)
£ 600
  • No waiting times
  • Includes Full Radiologist Report
  • Open or Closed MRI scan types
  • Copy of Scan on CD

Website Offer

Pre-Booked Online
£1130
£ 800
  • Initial Consultation
  • MRI Scan (Single Region)
  • Follow Up consultation
  • Same Day One Stop Visit
  • Full Medical and MRI scan Report
  • Copy of scan on CD
Popular

If you have any emergency Doctor’s need, simply call our 24 hour emergency

Your personal case manager will ensure that you receive the best possible care.

Call Now 

+44 844 589 2020
+44 203 973 8810